X-Ray Test Equipment




ECC X-Ray kVp Meter/Exposure Time Meter

Detailed Description
NEW! Built to Order
TYPICAL SALES LEAD TIME: 5-7 Business Days
WARRANTY: 2-year manufacturer warranty
ACCESSORIES: Operator Manual, Calibration Certificate, 4AA Batteries

Padded Cordura Carrying Case is an extra $45.

The Model 815 Measures the peak x-ray accelerating voltage from tungsten x-ray generators. To measure peak kV the user simply places the instrument in the beam and takes an x-ray. In addition to measuring kVp, the Model 815 also measures the exposure time and displays the x-ray waveform type. The Model 815 kVp Meter is optimized for Dental x-rays, but can be used on radiographic and fluoroscopic x-rays.

There is a high resolution mode which is used for measurements on older x-rays and x-rays with slow rise times.

The kVp Meter has a large display which is readable from outside the x-ray room.

Features

Small Hand Held Size
Easy to use
Non invasive
High Accuracy
Battery Operated
Two Year Warranty
Measures kVp and exposure time simultaneously
Compact size
Durable ABS Plastic Case
Custom Carrying Case Option

Typical Applications
Measurement of Exposure
Verification of peak x-ray voltage
Constancy checks
X-ray calibration
Quality Assurance
Measurement of X-ray Exposure Time
Half Value Layer determination
Troubleshooting and Repair of X-rays

To learn more, please review our kVp Instruction Manual (Adobe PDF) and printable kVp Model 815 Data Sheet (Adobe PDF).

Specifications
RANGE
45 to 125 kV

KVP ACCURACY
2% +/- 1 kV, at 25 to 100 mA
18 to 42 cm from head, for
Tungsten target x-ray tube with 1.5 mm Al equivalent filtration

EXPOSURE TIME ACCURACY

2% +/- 3 millisecond
Minimum exposure time is 100 millisecond

MINIMUM EXPOSURE TIME (kVp Measurement)
100 millisec - High Speed Mode (normal)
200 millisec - High Resolution Mode

MINIMUM CURRENT (mA)
7 mA at 50 kV, 10 cm from x-ray source
Also depends on focus / collimating

DISPLAY

0.4"(10.2mm) Liquid Crystal
8 Character Alphanumeric

POWER
4 AA Batteries accessible from bottom of case
Low Battery Indicator

BATTERY LIFE

48 hours continuous
Typically 9 months of normal use

CONTROLS/ INDICATORS
ON/OFF Switch
Illuminated push-button with green power-on indication

MODE Switch
Momentary push-button
8 Character Liquid Crystal Display

PHYSICAL SIZE
150 x 120 x 58.5 mm
5.9 x 4.7 x 2.3 inches

WEIGHT
0.7 kG (1.5 lb)

CONNECTIONS
None required for normal kVp measurement

OPTIONAL ACCESSORIES
Padded Cordura Carrying Case

X-Ray Test Equipment


NEW" ECC X-Ray Pulse Counter / Exposure Time Meter

Detailed Description
"NEW" X-ray Pulse Counter
Model 8700

WARRANTY: 2-year manufacturer warranty
ACCESSORIES: Operator manual, Calibration Certificate
TYPICAL SALES LEAD TIME: 7-10 Business days

Optional Accessories:
8700CC Carrying Case for Model 8700 - Padded Cordura: $45.00
8700RS Remote Sensor allowing operation of the pulse counter up to 10 feet from the X-Ray Head. This small weighted sensor sits under x-ray head with a cable that plugs into the 8700: $70.00
8700SC Oscilloscope cable that connects "Scope" output of the model 8700 to standard BNC oscilloscope input: $30.00

DESCRIPTION
The Model 8700 X-Ray Pulse Counter/ Exposure Time Meter is used to measure the time or duration of radiation output produced by a wide variety of x-ray generators. The x-ray sensor in the 8700 allows direct measurement of exposure from the x-ray head. Pulses produced by half wave and full- wave x-ray are measured as 60 or 120 pulses per second. For DC, capacitor discharge and 3-phase x-ray, the 8700 measures the exposure time in milliseconds.

When testing x-ray timers and controls, the time of relay contact can be measured using the AC input feature.

The Model 8700 is "self-resetting". There is no need to reset the instrument after each reading. The reading is stored after each exposure, holding until the next exposure.

RECENT IMPROVEMENTS
Wider Range
Increased sensitivity allows use with lower power x-rays
Wider dynamic range allows use with higher power x-rays
More accuracy on DC/Multiphase high power x-rays

Measurement ends at 70% of peak value eliminating inaccuracy due to slow tail.
Periodic calibration is not needed

Digital / microprocessor circuitry does not drift or lose accuracy over time.
New circuitry saves production time and parts cost, allowing us to keep our competitive prices.
Low power circuitry improves battery life.

FEATURES
Small Hand Held Size
AC or DC X-Rays
New High Accuracy Circuit
Self Resetting
Battery Operated
Two Year Warranty
Direct Exposure Reading or AC Input
Use for Medical or Dental X-Rays
Remote Sensor Option
No Periodic Calibration Needed
Custom Carrying Case Option
Durable ABS Plastic Case

TYPICAL APPLICATIONS
Measurement of Exposure
Quality Assurance
Verification of X-ray Exposure Time
Calibration of X-ray Timer
Direct Measurement of Timer Accuracy
Troubleshooting and Repair of x-ray

SPECIFICATIONS


ACCURACY
AC - one count
DC- 2% +/-1 millisecond

SENSITIVITY
X-ray input: 40kVp, 5mA at 5 cm from top surface of case, pointed to target
AC Input: 90 VAC minimum

RANGE
9999 Pulses
9999 Milliseconds

DISPLAY

0.4" Liquid Crystal

POWER
Internal 9 Volt Battery
Low Battery Indicator

BATTERY LIFE
48 hours continuous
Typically 9 months of normal use

CONTROLS/ INDICATORS
Three position switch
Pulse
Off
Milliseconds
4 digit liquid crystal display
0.4" characters
Low battery indicator
Oscilloscope output
Remote Sensor Input

PHYSICAL SIZE
80 x147x 40mm
3.15 x 5.8 x1.6 inches

CONNECTIONS
None required for direct exposure measurement
2 tip jacks for AC input
Jack for Remote Sensor Option
Jack for Oscilloscope Output

OPTIONAL ACCESSORIES
Remote sensor with 3 meter cable
Padded Cordura Carrying Case
Oscilloscope Interface Cable
Long Life Battery

PREOWNED" Biotek IDA-2 Infusion Device Analyzer




Detailed Description

CONDITION: 9.0 cosmetic scale (1-10)
ACCESSORIES: Operating Manual, syringe, stopcock, tubing
CALIBRATION: Current Calibration
WARRANTY: 6 months
This portable device quickly evaluates the operation of infusion devices with both steady and nonsteady flow patterns. A simple user interface removes the clutter form infusion pump testing. Use the instrument in manual or computer control modes

MODES OF OPERATION:
Steady Flow:
This mode performs direct flow measurement by timing the displacement of fluid within a known volume. Use this mode for testing devices that have steady flow patterns, such as a syringe driver. The sample size varies with the flow rate, to minimize the time to first reading.

NonSteady Flow:
This mode performs a volume measurement and derives the flow. This sample size is set at 1ml regardless of the flow rate. Use this mode to test infusion pumps with nonsteady flows and PCA's.

Occlusion Pressure:
Set the infusion pump to the manufacturer's recommended flow rate, and select occlusion on the Biotek IDA-2. Measurements will be displayed in mmHg or PSI. This measures the downstream occlusion on the infusion pump.

Priming:
Priming the Biotek IDA-2 is a simple technique using an enclosed syringe. Generally this talk ccan be done with less than 5ml of fluid, depending on the priming solution.

FEATURES:
--Quick, accurate measurements of steady and nonsteady flow devices
--Flow-rate, delivered-volume, and occlusion-pressure testing
--Portable (attaches on an IV-Pole).
--Simple setup and operation
--RS232/Printer ports
STANDARD ACCESSORIES:
Operating Manual
Drain Tubes
Stopcocks
Priming Syringe

SPECIFICATIONS:

Flow Rate:
1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy)
100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy)
1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy)

Volume:
1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy)
100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy)
1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy)

Occlusion:
0 to 35 PSI +/-5% of reading

Time to Perform Flow-Rate Measurement:
1ml/hr: 5min (normal), 60min (high accuracy)
100ml/hr: 25 sec (normal), 60 sec (high accuracy)
1000ml/hr: 5 sec (normal), 5 sec (high accuracy)

Power:
Operating Voltage (frequency): 115/230 VAC, switchable (50-60Hz)

Dimensions:
6.25" L x 9.75" W x 5.25" H (16cm L x 25cm W x 13cm H)

Weight: 5lbs (2.3kg)

"NEW" DALE601 Electrical Safety Analyzer



Detailed Description

NEW UNIT comes with one-year manufacture warranty against defect and workmanship
Description
The DALE601 Electrical Safety Analyzer is the industry's lowest priced full function Electrical Safety Analyzer
Unique to the DALE601 is its capability to make a broad range of external measurements. A clearly labeled single master function switch guides the user through a complete measurement procedure

The DALE601 measures Line Voltage, Instrument Current, Ground Resistance, Earth and Chassis Leakage Current, Patient Lead-to-Ground, Lead-to-Lead and Lead Isolation (M.A.P.) Current, External Gradient, Probe and Transducer Isolation Current and Point-to-Point Resistance.

The device also tests all 120-volt standard wall outlets for the proper wiring. The green and an amber light indicate five normal or fault conditions

Heavy-duty switches change polarity, open and close the neutral and select Chassis or Earth Leakage Current measurements. A four-wire Kelvin bridge eliminates reading errors in resistance due to cable length and contact resistance. True RMS measurements are provided for all current readings. The AAMI test load is utilized.

The DALE601 has five (5) universal EKG lead connectors that allow for any type of lead connection.There is also a single slide switch that gives the user a choice

Features

· Small, lightweight, self-contained portable instrument
· Master range meter delivers accurate measurment for each test
· Accurate test measurements with 4-wire Kelvin bridge
· Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
· Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground.
· All Leakage Current measurements are displayed directly in �Amps.
· Broad range of external measurements · Five (5) Universal EKG Lead Connectors
· The DALE601 is designed for 120 V operation

Specifications
Mains Voltage
117 Volts, 50/60 Hz

Instrument Current
Range: 0 - 19.99 Amps.
Resolution: 10 mA
Accuracy: 5 % R
Frequency:
DC & 25 Hz - 1kHz: 1.0% R
1KHz - 100 KHz: 2.5% R
100 KHz - 1 MHz: 5% R
Controls
1. Function Switch - 9 position rotary
2. Lead Switch - 6 position rotary
3. Neutral Switch - 2 position rocker (Open/Closed)
3. Neutral Switch - 2 position rocker (Open/Closed)
4. Polarity Switch - 3 position rocker (Normal/Off/Reversed)
5. Leakage Switch - 2 position rocker (Chassis/Earth)

DUT Power
117 VAC, 16 Amps@ 120 V, 10 Amps @ 230 V

Physical Size:
4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)

NEW" Fluke PS400 ECG/Arrhythmia Simulator



Detailed Description

**NEW** One year warranty parts and labor

The Fluke PS400 is a small ECG simulator packed with waveforms designed to verify accuracy of ECG machines, monitors and telemetry units
FEATURES:--Simple to use rotary knob
--Handheld--12
-Lead ECG Simulation
--12 Arrhythmias
--Universal ECG Jacks
--Autosequencing of performance waveforms

STANDARD ACCESSORIES
Operating Manual
Battery Eliminator
Carrying Case

OPTIONAL ACCESSORIES:
Service Manual

SPECIFICATIONS:
ECG Waveforms:
Normal Sinus rhythm: 30 to 240 BPM

Performance Waveforms:
Square: 2Hz
Sine: 10,40,50,60,100 Hz
Triangle: 2 Hz

Amplitudes:
0.5 to 2.0 mV

Arrhythmias:
Atrial Fibrillation
Second-Degree heart block type I
Right-Bundle branch block
Premature Atrial Contraction
Premature Ventricular Contraction
Run of 5 PVC's
Bigeminy
PVC R-on-T wave
Ventricular Tachycardia
Ventricular Fibrillation

PacerAutosequence:Pulse
Wave: 4.0 s/l mvSine Wave Bursts: 10,40,50,60,100 Hz
Triange Wave: 2 Hz
High-Level Output:0.5 V/mV, lead IPower:9V Alkaline batteryDimensions:5.2" L x 3.9" W x 1.4" H (13cm L x 10cm W x 4cm H)Weight:14.2oz (400g)