X-Ray Test Equipment
ECC X-Ray kVp Meter/Exposure Time Meter
Detailed Description
NEW! Built to Order
TYPICAL SALES LEAD TIME: 5-7 Business Days
WARRANTY: 2-year manufacturer warranty
ACCESSORIES: Operator Manual, Calibration Certificate, 4AA Batteries
Padded Cordura Carrying Case is an extra $45.
The Model 815 Measures the peak x-ray accelerating voltage from tungsten x-ray generators. To measure peak kV the user simply places the instrument in the beam and takes an x-ray. In addition to measuring kVp, the Model 815 also measures the exposure time and displays the x-ray waveform type. The Model 815 kVp Meter is optimized for Dental x-rays, but can be used on radiographic and fluoroscopic x-rays.
There is a high resolution mode which is used for measurements on older x-rays and x-rays with slow rise times.
The kVp Meter has a large display which is readable from outside the x-ray room.
Features
Small Hand Held Size
Easy to use
Non invasive
High Accuracy
Battery Operated
Two Year Warranty
Measures kVp and exposure time simultaneously
Compact size
Durable ABS Plastic Case
Custom Carrying Case Option
Typical Applications
Measurement of Exposure
Verification of peak x-ray voltage
Constancy checks
X-ray calibration
Quality Assurance
Measurement of X-ray Exposure Time
Half Value Layer determination
Troubleshooting and Repair of X-rays
To learn more, please review our kVp Instruction Manual (Adobe PDF) and printable kVp Model 815 Data Sheet (Adobe PDF).
Specifications
RANGE
45 to 125 kV
KVP ACCURACY
2% +/- 1 kV, at 25 to 100 mA
18 to 42 cm from head, for
Tungsten target x-ray tube with 1.5 mm Al equivalent filtration
EXPOSURE TIME ACCURACY
2% +/- 3 millisecond
Minimum exposure time is 100 millisecond
MINIMUM EXPOSURE TIME (kVp Measurement)
100 millisec - High Speed Mode (normal)
200 millisec - High Resolution Mode
MINIMUM CURRENT (mA)
7 mA at 50 kV, 10 cm from x-ray source
Also depends on focus / collimating
DISPLAY
0.4"(10.2mm) Liquid Crystal
8 Character Alphanumeric
POWER
4 AA Batteries accessible from bottom of case
Low Battery Indicator
BATTERY LIFE
48 hours continuous
Typically 9 months of normal use
CONTROLS/ INDICATORS
ON/OFF Switch
Illuminated push-button with green power-on indication
MODE Switch
Momentary push-button
8 Character Liquid Crystal Display
PHYSICAL SIZE
150 x 120 x 58.5 mm
5.9 x 4.7 x 2.3 inches
WEIGHT
0.7 kG (1.5 lb)
CONNECTIONS
None required for normal kVp measurement
OPTIONAL ACCESSORIES
Padded Cordura Carrying Case
X-Ray Test Equipment
NEW" ECC X-Ray Pulse Counter / Exposure Time Meter
Detailed Description
"NEW" X-ray Pulse Counter
Model 8700
WARRANTY: 2-year manufacturer warranty
ACCESSORIES: Operator manual, Calibration Certificate
TYPICAL SALES LEAD TIME: 7-10 Business days
Optional Accessories:
8700CC Carrying Case for Model 8700 - Padded Cordura: $45.00
8700RS Remote Sensor allowing operation of the pulse counter up to 10 feet from the X-Ray Head. This small weighted sensor sits under x-ray head with a cable that plugs into the 8700: $70.00
8700SC Oscilloscope cable that connects "Scope" output of the model 8700 to standard BNC oscilloscope input: $30.00
DESCRIPTION
The Model 8700 X-Ray Pulse Counter/ Exposure Time Meter is used to measure the time or duration of radiation output produced by a wide variety of x-ray generators. The x-ray sensor in the 8700 allows direct measurement of exposure from the x-ray head. Pulses produced by half wave and full- wave x-ray are measured as 60 or 120 pulses per second. For DC, capacitor discharge and 3-phase x-ray, the 8700 measures the exposure time in milliseconds.
When testing x-ray timers and controls, the time of relay contact can be measured using the AC input feature.
The Model 8700 is "self-resetting". There is no need to reset the instrument after each reading. The reading is stored after each exposure, holding until the next exposure.
RECENT IMPROVEMENTS
Wider Range
Increased sensitivity allows use with lower power x-rays
Wider dynamic range allows use with higher power x-rays
More accuracy on DC/Multiphase high power x-rays
Measurement ends at 70% of peak value eliminating inaccuracy due to slow tail.
Periodic calibration is not needed
Digital / microprocessor circuitry does not drift or lose accuracy over time.
New circuitry saves production time and parts cost, allowing us to keep our competitive prices.
Low power circuitry improves battery life.
FEATURES
Small Hand Held Size
AC or DC X-Rays
New High Accuracy Circuit
Self Resetting
Battery Operated
Two Year Warranty
Direct Exposure Reading or AC Input
Use for Medical or Dental X-Rays
Remote Sensor Option
No Periodic Calibration Needed
Custom Carrying Case Option
Durable ABS Plastic Case
TYPICAL APPLICATIONS
Measurement of Exposure
Quality Assurance
Verification of X-ray Exposure Time
Calibration of X-ray Timer
Direct Measurement of Timer Accuracy
Troubleshooting and Repair of x-ray
SPECIFICATIONS
ACCURACY
AC - one count
DC- 2% +/-1 millisecond
SENSITIVITY
X-ray input: 40kVp, 5mA at 5 cm from top surface of case, pointed to target
AC Input: 90 VAC minimum
RANGE
9999 Pulses
9999 Milliseconds
DISPLAY
0.4" Liquid Crystal
POWER
Internal 9 Volt Battery
Low Battery Indicator
BATTERY LIFE
48 hours continuous
Typically 9 months of normal use
CONTROLS/ INDICATORS
Three position switch
Pulse
Off
Milliseconds
4 digit liquid crystal display
0.4" characters
Low battery indicator
Oscilloscope output
Remote Sensor Input
PHYSICAL SIZE
80 x147x 40mm
3.15 x 5.8 x1.6 inches
CONNECTIONS
None required for direct exposure measurement
2 tip jacks for AC input
Jack for Remote Sensor Option
Jack for Oscilloscope Output
OPTIONAL ACCESSORIES
Remote sensor with 3 meter cable
Padded Cordura Carrying Case
Oscilloscope Interface Cable
Long Life Battery
PREOWNED" Biotek IDA-2 Infusion Device Analyzer
Detailed Description
CONDITION: 9.0 cosmetic scale (1-10)
ACCESSORIES: Operating Manual, syringe, stopcock, tubing
CALIBRATION: Current Calibration
WARRANTY: 6 months
This portable device quickly evaluates the operation of infusion devices with both steady and nonsteady flow patterns. A simple user interface removes the clutter form infusion pump testing. Use the instrument in manual or computer control modes
MODES OF OPERATION:
Steady Flow:
This mode performs direct flow measurement by timing the displacement of fluid within a known volume. Use this mode for testing devices that have steady flow patterns, such as a syringe driver. The sample size varies with the flow rate, to minimize the time to first reading.
NonSteady Flow:
This mode performs a volume measurement and derives the flow. This sample size is set at 1ml regardless of the flow rate. Use this mode to test infusion pumps with nonsteady flows and PCA's.
Occlusion Pressure:
Set the infusion pump to the manufacturer's recommended flow rate, and select occlusion on the Biotek IDA-2. Measurements will be displayed in mmHg or PSI. This measures the downstream occlusion on the infusion pump.
Priming:
Priming the Biotek IDA-2 is a simple technique using an enclosed syringe. Generally this talk ccan be done with less than 5ml of fluid, depending on the priming solution.
FEATURES:
--Quick, accurate measurements of steady and nonsteady flow devices
--Flow-rate, delivered-volume, and occlusion-pressure testing
--Portable (attaches on an IV-Pole).
--Simple setup and operation
--RS232/Printer ports
STANDARD ACCESSORIES:
Operating Manual
Drain Tubes
Stopcocks
Priming Syringe
SPECIFICATIONS:
Flow Rate:
1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy)
100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy)
1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy)
Volume:
1 to 100ml/hr: +/-4% (normal), +/-2% (high accuracy)
100 to 1000ml/hr: +/-2% (normal), +/-2% (high accuracy)
1000+ ml/hr: +/-4% (normal), +/-2% (high accuracy)
Occlusion:
0 to 35 PSI +/-5% of reading
Time to Perform Flow-Rate Measurement:
1ml/hr: 5min (normal), 60min (high accuracy)
100ml/hr: 25 sec (normal), 60 sec (high accuracy)
1000ml/hr: 5 sec (normal), 5 sec (high accuracy)
Power:
Operating Voltage (frequency): 115/230 VAC, switchable (50-60Hz)
Dimensions:
6.25" L x 9.75" W x 5.25" H (16cm L x 25cm W x 13cm H)
Weight: 5lbs (2.3kg)
"NEW" DALE601 Electrical Safety Analyzer
Detailed Description
NEW UNIT comes with one-year manufacture warranty against defect and workmanship
Description
The DALE601 Electrical Safety Analyzer is the industry's lowest priced full function Electrical Safety Analyzer
Unique to the DALE601 is its capability to make a broad range of external measurements. A clearly labeled single master function switch guides the user through a complete measurement procedure
The DALE601 measures Line Voltage, Instrument Current, Ground Resistance, Earth and Chassis Leakage Current, Patient Lead-to-Ground, Lead-to-Lead and Lead Isolation (M.A.P.) Current, External Gradient, Probe and Transducer Isolation Current and Point-to-Point Resistance.
The device also tests all 120-volt standard wall outlets for the proper wiring. The green and an amber light indicate five normal or fault conditions
Heavy-duty switches change polarity, open and close the neutral and select Chassis or Earth Leakage Current measurements. A four-wire Kelvin bridge eliminates reading errors in resistance due to cable length and contact resistance. True RMS measurements are provided for all current readings. The AAMI test load is utilized.
The DALE601 has five (5) universal EKG lead connectors that allow for any type of lead connection.There is also a single slide switch that gives the user a choice
Features
· Small, lightweight, self-contained portable instrument
· Master range meter delivers accurate measurment for each test
· Accurate test measurements with 4-wire Kelvin bridge
· Test method complies with AAMI load per ANSI/AAMI ES1-1993 or IEC601-1
· Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground.
· All Leakage Current measurements are displayed directly in �Amps.
· Broad range of external measurements · Five (5) Universal EKG Lead Connectors
· The DALE601 is designed for 120 V operation
Specifications
Mains Voltage
117 Volts, 50/60 Hz
Instrument Current
Range: 0 - 19.99 Amps.
Resolution: 10 mA
Accuracy: 5 % R
Frequency:
DC & 25 Hz - 1kHz: 1.0% R
1KHz - 100 KHz: 2.5% R
100 KHz - 1 MHz: 5% R
Controls
1. Function Switch - 9 position rotary
2. Lead Switch - 6 position rotary
3. Neutral Switch - 2 position rocker (Open/Closed)
3. Neutral Switch - 2 position rocker (Open/Closed)
4. Polarity Switch - 3 position rocker (Normal/Off/Reversed)
5. Leakage Switch - 2 position rocker (Chassis/Earth)
DUT Power
117 VAC, 16 Amps@ 120 V, 10 Amps @ 230 V
Physical Size:
4.0 x 7.8 x 1.6 inches (102 x 196 x 41 mm)
NEW" Fluke PS400 ECG/Arrhythmia Simulator
Detailed Description
**NEW** One year warranty parts and labor
The Fluke PS400 is a small ECG simulator packed with waveforms designed to verify accuracy of ECG machines, monitors and telemetry units
FEATURES:--Simple to use rotary knob
--Handheld--12
-Lead ECG Simulation
--12 Arrhythmias
--Universal ECG Jacks
--Autosequencing of performance waveforms
STANDARD ACCESSORIES
Operating Manual
Battery Eliminator
Carrying Case
OPTIONAL ACCESSORIES:
Service Manual
SPECIFICATIONS:
ECG Waveforms:
Normal Sinus rhythm: 30 to 240 BPM
Performance Waveforms:
Square: 2Hz
Sine: 10,40,50,60,100 Hz
Triangle: 2 Hz
Amplitudes:
0.5 to 2.0 mV
Arrhythmias:
Atrial Fibrillation
Second-Degree heart block type I
Right-Bundle branch block
Premature Atrial Contraction
Premature Ventricular Contraction
Run of 5 PVC's
Bigeminy
PVC R-on-T wave
Ventricular Tachycardia
Ventricular Fibrillation
PacerAutosequence:Pulse
Wave: 4.0 s/l mvSine Wave Bursts: 10,40,50,60,100 Hz
Triange Wave: 2 Hz
High-Level Output:0.5 V/mV, lead IPower:9V Alkaline batteryDimensions:5.2" L x 3.9" W x 1.4" H (13cm L x 10cm W x 4cm H)Weight:14.2oz (400g)
Wednesday, October 1, 2008
Transport Ventilator
v Four operating modes: CMV, A/CMV, SIMV, SPONT
v Lightweight, durable and simple to use
v Ventilation volume and ventilation frequency can be adjusted insuccession and separately
v LCD graphical display to indicate airway pressure, alarm limits, tidal volume, mode
v Automatic pressure relief valve for airway pressure more than 6KPa
v Air-oxygen blender prolongs the operating time during long-time transportation
v Audiovisual low input pressure alarm and over input pressure protection
VENTILATOR PARAMETERS Tidal Volume (at C mode) Flow (atA/C, SIMV mode) Breath Rate %02 Spont Flow Sigh Inspiratory timeTrigger Level PIP Silence
ALARMS AND INDICATORS High Pressure Alarm LimitLow Pressure Alarm LimitAlarm IndicatorOver Pressure ReliefMain Circuit Pressure (Paw)
RANGE 50~1200ml Low, Med, High 5~60 bpm, 1~12 bpm for SIMV 45%~90% 0~5 UMin 1 per 0-100 breath cycle 0.5~3 s -10~0 hpa 0~60 hpa 60s 20~-60hpa (to be set) 2~20hpa (to be set) Flashing Red Indicator < 60 hpa -2~10kPa
ELECTRICAL SPECIFICATIONS INPUT POWER SUPPLY DC Voltage: 12 V Power : 10VA CHARGER AC Voltage: 100 ~ 240 V, 50/60 Hz Power : 25 VA
PNEUMATIC SPECIFICATIONS Oxygen InletPressuried Oxygen: 0.40 Mpa, 60 L/min.
PHYSICAL 300mm (W) x 140mm (D) x 230mm (H) Weight
-------------------------------------------------------------------------------------
ICU-VENTILATORS
Capable to provide continuous or intermittent ventilatory support for individuals who require mechanical ventilation
Can be used for adult, pediatric and neonate patients
Easy to use VENTURI pneumatic system, microprocessor-based Ventilatory system capable of provide excellent gas delivery and patient monitoring
Capable to provide continuous or intermittent ventilatory support for individuals who require mechanical ventilation
Can be used for adult, pediatric and neonate patients
Easy to use VENTURI pneumatic system, microprocessor-based Ventilatory system capable of provide excellent gas delivery
-----------------------------------------------------------------------------------------
HUMIDIFIER
HEATING CHARACTERISTIC Temperature Range 1~9 steps (Relative to 45°C~75°C) Temperature of Heater <75°c> Type Alcoholic temp Measuring Range 20°C~50°C Measuring Accuracy 1 %
PHYSICAL 135mm(W) x 170mm(H) x 156mm(D)Weight (Non-Loading Heat Tank) 1.3kg (max) Weight (Loading Heat Tank & Water) 1.6kg (max)
--------------------------------------------------------------------------------------
Subscribe to:
Posts (Atom)