Wednesday, October 1, 2008




Transport Ventilator


v Four operating modes: CMV, A/CMV, SIMV, SPONT
v Lightweight, durable and simple to use
v Ventilation volume and ventilation frequency can be adjusted insuccession and separately
v LCD graphical display to indicate airway pressure, alarm limits, tidal volume, mode
v Automatic pressure relief valve for airway pressure more than 6KPa
v Air-oxygen blender prolongs the operating time during long-time transportation
v Audiovisual low input pressure alarm and over input pressure protection
VENTILATOR PARAMETERS Tidal Volume (at C mode) Flow (atA/C, SIMV mode) Breath Rate %02 Spont Flow Sigh Inspiratory timeTrigger Level PIP Silence
ALARMS AND INDICATORS High Pressure Alarm LimitLow Pressure Alarm LimitAlarm IndicatorOver Pressure ReliefMain Circuit Pressure (Paw)
RANGE 50~1200ml Low, Med, High 5~60 bpm, 1~12 bpm for SIMV 45%~90% 0~5 UMin 1 per 0-100 breath cycle 0.5~3 s -10~0 hpa 0~60 hpa 60s 20~-60hpa (to be set) 2~20hpa (to be set) Flashing Red Indicator < 60 hpa -2~10kPa
ELECTRICAL SPECIFICATIONS INPUT POWER SUPPLY DC Voltage: 12 V Power : 10VA CHARGER AC Voltage: 100 ~ 240 V, 50/60 Hz Power : 25 VA
PNEUMATIC SPECIFICATIONS Oxygen InletPressuried Oxygen: 0.40 Mpa, 60 L/min.
PHYSICAL 300mm (W) x 140mm (D) x 230mm (H) Weight
-------------------------------------------------------------------------------------
ICU-VENTILATORS



Capable to provide continuous or intermittent ventilatory support for individuals who require mechanical ventilation
Can be used for adult, pediatric and neonate patients
Easy to use VENTURI pneumatic system, microprocessor-based Ventilatory system capable of provide excellent gas delivery and patient monitoring
Capable to provide continuous or intermittent ventilatory support for individuals who require mechanical ventilation
Can be used for adult, pediatric and neonate patients
Easy to use VENTURI pneumatic system, microprocessor-based Ventilatory system capable of provide excellent gas delivery

-----------------------------------------------------------------------------------------


HUMIDIFIER
HEATING CHARACTERISTIC Temperature Range 1~9 steps (Relative to 45°C~75°C) Temperature of Heater <75°c> Type Alcoholic temp Measuring Range 20°C~50°C Measuring Accuracy 1 %

PHYSICAL
135mm(W) x 170mm(H) x 156mm(D)Weight (Non-Loading Heat Tank) 1.3kg (max) Weight (Loading Heat Tank & Water) 1.6kg (max)
--------------------------------------------------------------------------------------